To have your own number range, proceed the next steps.
In t-code OIEN (or SPRO: Plant Maintenance and Customer Service -- Master Data in Plant Maintenance and Customer Service -- Technical Objects -- Equipment -- Equipment Categories -- Define Number Ranges) define group and NR for group for object EQUIP_NR:
In t-code OIS2 - create new serial number profile with equipment category X (SPRO: Plant Maintenance and Customer Service -- Master Data in Plant Maintenance and Customer Service -- Technical Objects -- Serial Number Management -- Define Serial Number Profiles) :
Create new material master with SN profile X001, Serialization Level = 1 Keep equipment number and serial number synchronous:
In t-code OIET (or SPRO: Plant Maintenance and Customer Service -- Master Data in Plant Maintenance and Customer Service -- Technical Objects -- Equipment -- Equipment Categories -- Maintain Equiment Category) create new equipment category (X for ex., copy from S)
In t-code OIEN (or SPRO: Plant Maintenance and Customer Service -- Master Data in Plant Maintenance and Customer Service -- Technical Objects -- Equipment -- Equipment Categories -- Define Number Ranges) define group and NR for group for object EQUIP_NR:
Assign group with NR to equipment category
In t-code OIS2 - create new serial number profile with equipment category X (SPRO: Plant Maintenance and Customer Service -- Master Data in Plant Maintenance and Customer Service -- Technical Objects -- Serial Number Management -- Define Serial Number Profiles) :
Inside profile, define Serializing procedures, where you will be generate SN, with Equipment Requirement = 02 always with equipment:
Create new material master with SN profile X001, Serialization Level = 1 Keep equipment number and serial number synchronous:
If you do not see the button Create Serial Number Automatically, just check if Indicator: Serial Number Existence Requirement is OFF (OIS2 t-code):
If you create Purchase Order through BAPI_PO_CREATE1 just populate SERIALNO field (SERIALNUMBER structure) by SN from external number range:
Serial number: maintain batch for batch management requirement
Message no. MEEXTFU021
Clean up UII and save PO.
Some additional info about the matter is here
http://saphelp.ucc.ovgu.de/NW750/EN/78/0eb753128eb44ce10000000a174cb4/frameset.htm